Online and offline condition monitoring devices German technology is made By Eaton – internormen. (Certified & Calibrated )
– OCM01
- Supply operation pressure: -0,2…40 bar
- Viscosity range: 1…780mm²/s
- Temperature range of the oil: 0…70°
- Ambient temperature range: 0…50 °C
Measurements:
1- Solid contaminants According to NAS 1638. ISO 4406, SAE AS4059. Accuracy: ±1
2- Water Content AS PPM and water saturation %,
3- temperature,32 to 158 °F (0 to 70 °C).
4- Dynamic viscosity: 5 to 1,000 mPas.
5- -Relative dielectric constants: 1 to 10.
– CCS4
- operation pressure: 1.5 …… 420 bars
- Viscosity range: 1…400 mm²/s
- Temperature range of the oil: 0…70°
- Ambient temperature range: 0…50 °C
Measurements:
1- Solid contaminants According to NAS 1638. ISO 4406, SAE AS4059. Accuracy: ±1
2- Water Content AS PPM and water saturation %,
3- temperature,32 to 158 °F (0 to 70 °C).