Sunday, Aug 01, 2010

Fluid Purifieres

Water is one of the most common contaminants and the second most destructive besides particulate contamination. Some of the most damaging problems water contamination can cause are:

Fluid breakdown- Additive depletion -Reduction of the lubrication properties of the fluid -Oil oxidation - Internal corrosion - Abrasive wear in system components - Reduced dielectric strength.
Principle of Operation:

Contaminated fluid is drawn into the Internormen Fluid Purifier System by a vacuum of 0,6 to 0,9 bars.
The fluid is passing a heater which is raising the temperature in order to increase the filtration speed.
The fluid then enters through a vacuum actuated inlet valve into the vacuum chamber, where it is then allowed to cascade over the dispersal elements to break it into droplets in the tower. This increases the exposed surface area of the fluid and converts the water into vapour form, which is drawn out of the tower with a vacuum pump through the condenser to the drainage reservoir for drain off. The water-free fluid is drawn out of the tower by a hydraulic pump and sent through a high efficiency particulate removal filter back to the system.
The installed water sensor allows a permanent control of the saturation of the fluid

 

ifpm21

IFPM 21

Technical data:  pdf
Inlet connection: 1 ½” SAE-flange 3000 PSI
Outlet connection: 1 ¼ ” SAE-flange 3000 PSI
Circulation flow rate:* 20 l/min
Operating vacuum:** 0,6 to 0,9 bar
E-motor hydraulic pump: 0,55 KW, 3-phase 230/400V, 50 Hz
E-motor vacuum pump: 0,55 KW, 3-phase 230/400V, 50 Hz
Heater capacity: 3000 Watt
Filter type: NF 631
sealing material: Viton (FPM)
Maximum viscosity: 700 mm²/s
Water extraction rate:*** 75 l/Day
weight: approx. 315 kg

 

IFPM 31

Technical data: ifpm31pdf
Inlet connection: 1 ½” SAE-flange 3000 PSI
Outlet connection: 1 ¼ ” SAE-flange 3000 PSI
Circulation flow rate:* 30 l/min
Operating vacuum:** 0,6 to 0,9 bar
E-motor hydraulic pump: 0,75 KW, 3-phase 230/400V, 50 Hz
E-motor vacuum pump: 0,55 KW, 3-phase 230/400V, 50 Hz
Heater capacity: 3000 Watt
Filter type: NF 631
sealing material: Viton (FPM)
Maximum viscosity: 700 mm²/s
Water extraction rate:*** 105 l/Day
weight: approx. 325 kg
* Viscosity of the liquid of 32 mm²/s
** Operating vacuum adapted to the specific application
*** Initial rate purifying mineral oil at 32 mm²/s, 40°C and with 6% water content

 

ifpm71IFPM 71

Technical data: pdf

Inlet connection: 2 ½” SAE-flange 3000 PSI
Outlet connection: 2 ” SAE-flange 3000 PSI
Circulation flow rate:* 70 l/min
Operating vacuum:** 0,6 to 0,9 bar
E-motor hydraulic pump: 1,50 KW, 3-phase 230/400V, 50 Hz
E-motor vacuum pump: 1,25 KW, 3-phase 230/400V, 50 Hz
Heater capacity: 4000 Watt
Filter type: NF 1000
sealing material: Viton (FPM)
Maximum viscosity: 700 mm²/s
Water extraction rate:*** 315 l/Day
weight: approx. 590 kg

 

ifps71IFPS 71

Technical data: pdf
Inlet connection: 2 ½” SAE-flange 3000 PSI
Outlet connection: 2 ” SAE-flange 3000 PSI
Circulation flow rate:* 70 l/min
Operating vacuum:** 0,6 to 0,9 bar
E-motor hydraulic pump: 1,50 KW, 3-phase 230/400V, 50 Hz
E-motor vacuum pump: 1,25 KW, 3-phase 230/400V, 50 Hz
Heater capacity: 4000 Watt
Filter type: NF 1000
sealing material: Viton (FPM)
Maximum viscosity: 700 mm²/s
Water extraction rate:*** 315 l/Day
weight: approx. 590 kg

ifps101IFPS 101

Technical data: pdf
Inlet connection: 3″ SAE-flange 3000 PSI
Outlet connection: 2 ½” SAE-flange 3000 PSI
Circulation flow rate:* 100 l/min
Operating vacuum:** 0,6 to 0,9 bar
E-motor hydraulic pump: 2,2 KW, 3-phase 230/400V, 50 Hz
E-motor vacuum pump: 1,8 KW, 3-phase 230/400V, 50 Hz
Heater capacity: 8000 Watt
Filter type: 2x NF 1000
sealing material: Viton (FPM)
Maximum viscosity: 700 mm²/s
Water extraction rate:*** 450 l/Day
weight: approx. 790 kg
* Viscosity of the liquid of 32 mm²/s
** Operating vacuum adapted to the specific application
*** Initial rate purifying mineral oil at 32 mm²/s, 40°C and w ith 6% water content