• Water is one of the most common contaminants and the second most destructive besides particulate contamination. Some of the most damaging problems water contamination can cause are:

    Fluid breakdown- Additive depletion -Reduction of the lubrication properties of the fluid -Oil oxidation - Internal corrosion - Abrasive wear in system components - Reduced dielectric strength.
    Principle of Operation:

    Contaminated fluid is drawn into the Internormen Fluid Purifier System by a vacuum of 0,6 to 0,9 bars.
    The fluid is passing a heater which is raising the temperature in order to increase the filtration speed.
    The fluid then enters through a vacuum actuated inlet valve into the vacuum chamber, where it is then allowed to cascade over the dispersal elements to break it into droplets in the tower. This increases the exposed surface area of the fluid and converts the water into vapour form, which is drawn out of the tower with a vacuum pump through the condenser to the drainage reservoir for drain off. The water-free fluid is drawn out of the tower by a hydraulic pump and sent through a high efficiency particulate removal filter back to the system.
    The installed water sensor allows a permanent control of the saturation of the fluid

     

    ifpm21

    IFPM 21

    Technical data:  pdf
    Inlet connection: 1 ½” SAE-flange 3000 PSI
    Outlet connection: 1 ¼ ” SAE-flange 3000 PSI
    Circulation flow rate:* 20 l/min
    Operating vacuum:** 0,6 to 0,9 bar
    E-motor hydraulic pump: 0,55 KW, 3-phase 230/400V, 50 Hz
    E-motor vacuum pump: 0,55 KW, 3-phase 230/400V, 50 Hz
    Heater capacity: 3000 Watt
    Filter type: NF 631
    sealing material: Viton (FPM)
    Maximum viscosity: 700 mm²/s
    Water extraction rate:*** 75 l/Day
    weight: approx. 315 kg

     

    IFPM 31

    Technical data: ifpm31pdf
    Inlet connection: 1 ½” SAE-flange 3000 PSI
    Outlet connection: 1 ¼ ” SAE-flange 3000 PSI
    Circulation flow rate:* 30 l/min
    Operating vacuum:** 0,6 to 0,9 bar
    E-motor hydraulic pump: 0,75 KW, 3-phase 230/400V, 50 Hz
    E-motor vacuum pump: 0,55 KW, 3-phase 230/400V, 50 Hz
    Heater capacity: 3000 Watt
    Filter type: NF 631
    sealing material: Viton (FPM)
    Maximum viscosity: 700 mm²/s
    Water extraction rate:*** 105 l/Day
    weight: approx. 325 kg
    * Viscosity of the liquid of 32 mm²/s
    ** Operating vacuum adapted to the specific application
    *** Initial rate purifying mineral oil at 32 mm²/s, 40°C and with 6% water content

     

    ifpm71IFPM 71

    Technical data: pdf

    Inlet connection: 2 ½” SAE-flange 3000 PSI
    Outlet connection: 2 ” SAE-flange 3000 PSI
    Circulation flow rate:* 70 l/min
    Operating vacuum:** 0,6 to 0,9 bar
    E-motor hydraulic pump: 1,50 KW, 3-phase 230/400V, 50 Hz
    E-motor vacuum pump: 1,25 KW, 3-phase 230/400V, 50 Hz
    Heater capacity: 4000 Watt
    Filter type: NF 1000
    sealing material: Viton (FPM)
    Maximum viscosity: 700 mm²/s
    Water extraction rate:*** 315 l/Day
    weight: approx. 590 kg

     

    ifps71IFPS 71

    Technical data: pdf
    Inlet connection: 2 ½” SAE-flange 3000 PSI
    Outlet connection: 2 ” SAE-flange 3000 PSI
    Circulation flow rate:* 70 l/min
    Operating vacuum:** 0,6 to 0,9 bar
    E-motor hydraulic pump: 1,50 KW, 3-phase 230/400V, 50 Hz
    E-motor vacuum pump: 1,25 KW, 3-phase 230/400V, 50 Hz
    Heater capacity: 4000 Watt
    Filter type: NF 1000
    sealing material: Viton (FPM)
    Maximum viscosity: 700 mm²/s
    Water extraction rate:*** 315 l/Day
    weight: approx. 590 kg

    ifps101IFPS 101

    Technical data: pdf
    Inlet connection: 3″ SAE-flange 3000 PSI
    Outlet connection: 2 ½” SAE-flange 3000 PSI
    Circulation flow rate:* 100 l/min
    Operating vacuum:** 0,6 to 0,9 bar
    E-motor hydraulic pump: 2,2 KW, 3-phase 230/400V, 50 Hz
    E-motor vacuum pump: 1,8 KW, 3-phase 230/400V, 50 Hz
    Heater capacity: 8000 Watt
    Filter type: 2x NF 1000
    sealing material: Viton (FPM)
    Maximum viscosity: 700 mm²/s
    Water extraction rate:*** 450 l/Day
    weight: approx. 790 kg
    * Viscosity of the liquid of 32 mm²/s
    ** Operating vacuum adapted to the specific application
    *** Initial rate purifying mineral oil at 32 mm²/s, 40°C and w ith 6% water content