Installation in all IFPM devices |
| AG2 can be installed directly into the control panel, all important parameters at a glance |
| The integration of the VS01 brings additional analogue indication of filter contamination |
| Device to interpret the electric signals coming from the VS1 and the WS02 |
| Setting position reading via LED |
| Cold start indication via LED |
| Adjustable preasure peak rejection |
Applications:
|
| This combination enables you to monitor the saturation and contamination level of your oil continuously. |
| The WS01 in combination with the AG2 and the VS01 is applicable in all common hydraulic and lubricating systems. |
Indication of the saturation level:
|
| 10-step LED – display “AG2″ |
| 00 – 60 % no free water |
| 60 – 80 % small amounts of free water |
| 80 – …..% free water present |
Technical data:
|
| Measuring range: |
0…100% Saturation |
| Tolerance: |
(MR 5…95% at 10..40°C): ± 2% |
| Additional error: |
( > 40°C): 0,1%/K |
| Ambient temperature: |
-40°C…+80°C |
| Output signal: |
4…20 mA |
| Operating voltage: |
12…30 V |
| Acceptable burden for 24 VDC: |
600 Ohm |
| Supply voltage: |
24 V DC ± 20 % |
| Periodic and random deviation: |
< 10 % |
| Relay contacts: |
2 x shutter |
| Umax: |
240 V AC |
| Imax: |
0,5 A |
| Pmax: |
10 Watts |
| Temperature range: |
0 – 70 °C |
| Protection class: |
IP 53 (only front with clear screen) |
| Enclosure dimensions: |
based on DIN 43700 (see figure below) |