| Mobile diagnostic system able to determine the ageing condition of oil in hydraulic and lubrication systems by measuring solid contamination, water saturation, temperature, viscosity and relative dielectricity.
Applicable for both pressure and suction lines (can as well be used when working with foamed oils in gears).
Enables the user to make a precise assessment of the condition of a system and perform a cost-effective maintenance on time.
A guarantee for permanently available and highly efficient systems!
|
|
Technical Data:
|
|
|
| Operating parameters: |
|
| Voltage supply: |
90…230V, 50/60 Hz |
| Pressure operating range: |
-0,2…40 bar |
| Viscosity range: |
1…400 mm²/s |
| Max. permited oil temperature: |
0…70°C |
| Ambient temperature: |
0…50°C |
| Protection class: |
IP 67 (if the top cover is closed) |
|
|
| Measurement parameters: |
|
| Particle counting according to ISO 4406:99, NAS 1638, SAE AS 4059 |
|
| Automatic particle counting in 8-channels: 4,0 µm(c) , 4,6 µm(c) , 6,0 µm(c) , 6,4 µm(c) , 10 µm(c) , 14 µm(c) , 21 µm(c) , 37 µm(c) |
| Coincidence boundary: |
10 000 particle / ml |
| Calibration: |
ISO MTD in oil (ISO 11171:2000) |
| Measuring accuracy: |
± 1 (contamination classes) |
| Water saturation: |
0…100% |
| Dynamic viscosity: |
5…1500 mPas |
| Temperature: |
0…70°C |
| Dynamic viscosity: |
0,8…320 mPas |
| Relative dielectricity constant: |
1…10 |
|