| In-line multifunction sensor meant for oil condition monitoring in hydraulic and lubrication systems.
Able to determine the ageing condition of oil and detect various mixtures by measuring (absolute parameters) and detecting changes of viscosity, temperature and relative dielectricity before system failures can occur.
Enables the user to programme an automatic oil condition monitoring function, make a precise assessment of the condition of a system and perform maintenance accurately timed.
|
|
Technical Data:
|
|
|
| Operating parameters: |
|
| Max. admissible pressure: |
25 bar |
| Ambient temperature: |
-40…70°C |
| Power supply: |
24 VDC |
| Output interface: |
analogue 4..20mA |
|
(viscosity / temperature / rel. dielectricity / oil condition) |
|
or CAN-Open (instead of the analogue output) |
Connection thread:
|
G ¾
|
Protection class:
|
IP 65
|
|
|
| Measurement parameters: |
|
| Dynamic viscosity: |
5…1500 mPas
|
| Temperature: |
-30…130°C |
| Relative dielectricity constant: |
1…10 |
| Accuracy of measurements: |
Viscosity: ±2,5 |
|
Temperature: ±0,5°C |
|
Rel. dielectricity constant: ±0,15 |
| Reproducibility viscosity/temperature: |
±1% |