Oil Conditions Monitoring Service.

ocm01EHP announce a new oil service for Egyptian Market, to  control oil by  OCM 01 ( multi-analysis system ).

 

What can we measure ?

1- Solid contaminants Acc NAS 1638. ISO 4406,

SAE AS4059.  Accuracy: ±1

2- Water Content AS PPM and water saturation %,

3- temperature,32 to 158 °F (0 to 70 °C).

4- Dynamic viscosity: 5 to 1,000 mPas.

5- -Relative dielectric constants: 1 to 10.

 Fields of application – compatibility Applicable for:

– Hydraulic oils H, HL, HLP, and HV.
– Gear oils C, CL, CLP.
– Motor oils, gas oils.
– MIL-H-5606 E.
– Vegetable based oils (HTG, triglycerides).
– Synthetic esters (HEES).

Technical data Operating parameters:-

– Operating suction range: – ( off line ) 2.9 to 2.9 psi (-0.2 to 0.2 bar).

Operating pressure range: ( On line )2.9 to 580 psi (0.2 to 40 bar).

– Viscosity: 200 to 3,615 SUS (45 to 780 mm2 /s).

– Fluid temperature: 32 to 158 °F (0 to 70 °C)

– Ambient temperature: 32 to 122 °F (0 to 50 °C).

How it Can Help ?

– Measuring Water content in PPM in the same time will let you avoid confusion between solid and water contamination, which will help you to take the right decision, Filtration or dehydration.

– Relative Dielectric constant became a very important factor to evaluate the oil general conditions, because it affected by PH No, Oxidation, Additives, Viscosity.

– You can monitor  the all parameter in the same time.

Notice : EHP can offer this service to be done in your site or EHP lab,

Example of Measurement Display :

ocm01 display